Cleanrooms

Cleanrooms solutions allow product protection in a variety of materials and configurations.

FPS may design and install turnkey solutions, up to ISO8 classification, complete with:

  • Partitioning walls, manufactured with high pressure laminated sheets, stainless steel, carbon steel, complete with coving and accessories when required, access doors, windows.
  • The whole system is designed assuring co-planar surfaces with best cleaning results. 
  • HVAC systems, with required air flows and HEPA filtration according to desired ISO class and containment needs. The HVAC is complete with the T and RH control system; it is possible to design the system assuring special thermo-hygrometric conditions, down to RH<20%.
  • Flooring, with PVC mats or epoxy resins lining.
  • Illumination of rooms with LED or neon lamps.
  • Access control system, to prevent direct communication of external environment with working areas (available even in ATEX rated areas).
  • Qualification documentation.
  • Qualification service.

STS - Swab Testing Station for Covid-19

FPS is pleased to announce the launch of a new innovating solution for swabbing, that will ensure the absolute safety of operators and patients: the Swab Testing Station (STS).

Inspired by the Korean hospital of Yangji in Seoul, FPS has designed and constructed the first system to safely swab potentially infected patients by healthcare personnel located outside the station.

Tests only take a few minutes and are very safe because both the operator and the patient are never in direct contact. The cabins are easily transportable and, once positioned at strategic points (entrances of hospitals, pharmacies, neighborhoods, squares...), the STS will allow operators to perform 10 swabs in one hour. 

The Swab Testing Station includes a completely safe removal system for the waste generated by the swabbing activities by means of a special container inside each cabin.

The STS is composed of 2 cabins and each is equipped with powerful ventilation that speeds up the aeration phase after sanitization to reduce the downtime between tests. The ventilation also allows the achievement of negative dynamic pressure inside each of the two cabins. Best in class filtration dramatically reduces the risk of potentially contaminated air escaping the station.

An intercom allows clear communication between the patient and the operator with the possibility to use pre-recorded audio with standard instructions (which can be done in different languages).

Carlo Corsini, FPS owner and General Manager, says: “I’m very proud of the FPS team for working together and putting their technical skills at the service of public health on such short notice. The team worked with enthusiasm despite the difficulties that we are all going through at this time

 
Click HERE for the video presentation and HERE the operating video